The product is a new saving-energy switch
adopting the good sensitivity detector, interated circuit and SMT. It gathers
automatic, convenient, safe, saving-energy and practical functions.The wide
detection field is made up of up and
down, left and right service field. It works by receiving human motion
infrared rays. Whe one enters the detection fields, it can start the load at
once and identify day and night automatically;It can be used with various types
of lamp and lanterns.
Specifications:
Power source:220-240VAC
Power frequency:50HZ
Rated load:220W Max.tungsten
25W Max.fluorescent
Time setting:(8±2)S-(6±2)Min(adjustable)
Light-control:<10LUX~2000LUX(adjustable)
Detection range:8 m Max(dia.) (adjustable)
Detection angle:360°
Installation height:2.5m~3.5m
Working temperature:-10~+40℃
Detection motion speed:0.6-1.5m/s
Working humidity:<93%RH
Function
Detection field: the detection field is
made up and down,left and service field, it can be selected according to the
consumer’s desire.But the moving orientation has great relationship with the
sensitivity.
Can identify day and night: the light
control can e adjusted freely when it works . It can work in the daytime and at
night when it is adjusted on the “sun” position(max); but it can only work in
the light control less than 10lux when it is adjusted on the “moon”
position(min).As for the adjustment pattern,please refer to the testing
pattern.
Time delay can be added continually:when it
received the second induction signal after the first it will compute time once
more on the rest of the first time delay basic(set time).
Light-control potentiometer(LUX):clockwise
the knob to increase its value; anti-clockwise the knob to decrease its value.
Time potentiometer(TIME):clowise the knob
to increase its value, the maximum delay time is(6±2)minutes;
anti-clockwise the knob to decrease its value, the minimum delay time is
(8±2)seconds.
Sensitivity potentiometer(SENS):clockwise
the knob to increase its value, the maximum distance is 8m(dia).
Installation(see the
following diagram)
Switch off the power
Set threaded tubes
into the power cord and control line
Connect the power and
the load with the sensor according to the connection-line diagram
TEST
1.
Turn the
light-control potentiometer to Max value, the time delay potentiometer to Min
value, the sensitivity potentiometer to Max value, and then switch on the
power.The product will enter into normal working state thirty seconds later. Wave
your hand in the right front of the sensor window after the indicator switches
off, then the sensor will start load to work when it has detected the signal.
In the event of no continuous detection, the load will stop working in 8±2s
2.
Turn the light-control potentiometer to
Min value, wave your hand in the right front of the sensor window after the
indicator switches off, the load won’t work.Cover the sensor window with PIECE OF NON-TRANSPARENT BLACK CLOTH, THE
LOAD STARTS WORKING. In the event of no continuous detection, the load will
stop working in 8±2s
3.
Turn the light-control potentiometer to
Max value, the time delay potentiometer to Max value, the sensitivity
potentiometer to Max value.Wave your hand in the tight front of the sensor
window after the indicator switches off, then the sensor will start load to
work when it has detected the signal . In the event of no continuous detection,
the ;load will stop working in 8±2s
ATTENTION:When use this product, please adjust
the sensitivity to an appropriate position you need, please do not adjust the
sensitivity to maimun,to avoid the product does not work normally caused by
wrong motion.Because the sensitivity is too high easily detect the wrong moion
by wind blowing leaves&curtains,small animals,and the wrong motion by
interence of power grid&electrical equipment.All those lead product dose
not work normally!
When the product does not work normally ,please
try to lower the sensitivity appropriately,
And then test it.
Notes:
Electrician or experienced human can install it
The unrest objects can’t be regarded the
installation basis-face
In front of the detection windw there should be
no hinder or unrest objects effecting detection
Avoid installing it near air temperature alteration
zones for example:air condition,central heating,ect.
Please don’t open the case for your safety if
you find the hitch after installation
Remark
1.
Keep the sensor face to the area where
human usually move
2.
Keeo the sensor face to the position of
the ambient light in order to get much more exact illuminance setting
3.
If detect the signal again within the
time-delay, the time-delay will ba over lied
Some problem and solved way
The load don’t work:
A:Check the power and the load
b.If the load is good
c.olease check
if the working light correspond to the ambient light
The sensitivity is poor:
a.
Please check if in front of the
detection window there is hinder that effect to receive the signals
b.
Please check if the ambient temperature
is too high
c.
Please check if the signals source is in the detection fields
d.
If the moving orientation is right
The sensor can’t shut automatically the load:
a.
If there is continual signal in the
detection fields
b.
If the time delay is set to the longest
c.
If the power correspond to the
instruction
d.
If the air temperature change near the
sensor, for example air condition or central heating ect