2018年8月9日星期四

concealed sprinkle cup


The product is a new saving-energy switch adopting the good sensitivity detector, interated circuit and SMT. It gathers automatic, convenient, safe, saving-energy and practical functions.The wide detection field is made up of up and  down, left and right service field. It works by receiving human motion infrared rays. Whe one enters the detection fields, it can start the load at once and identify day and night automatically;It can be used with various types of lamp and lanterns.

Specifications:

Power source:220-240VAC
Power frequency:50HZ
Rated load:220W Max.tungsten
         25W Max.fluorescent
Time setting:(8±2)S-(6±2)Min(adjustable)
Light-control:<10LUX~2000LUX(adjustable)
Detection range:8 m Max(dia.) (adjustable)
Detection angle:360°
Installation height:2.5m~3.5m
Working temperature:-10~+40
Detection motion speed:0.6-1.5m/s
Working humidity:<93%RH

Function
Detection field: the detection field is made up and down,left and service field, it can be selected according to the consumer’s desire.But the moving orientation has great relationship with the sensitivity.

Can identify day and night: the light control can e adjusted freely when it works . It can work in the daytime and at night when it is adjusted on the “sun” position(max); but it can only work in the light control less than 10lux when it is adjusted on the “moon” position(min).As for the adjustment pattern,please refer to the testing pattern.

Time delay can be added continually:when it received the second induction signal after the first it will compute time once more on the rest of the first time delay basic(set time).

Light-control potentiometer(LUX)clockwise the knob to increase its value; anti-clockwise the knob to decrease its value.

Time potentiometer(TIME):clowise the knob to increase its value, the maximum delay time is(6±2)minutes; anti-clockwise the knob to decrease its value, the minimum delay time is (8±2)seconds.

Sensitivity potentiometer(SENS):clockwise the knob to increase its value, the maximum distance is 8m(dia).

Installation(see the following diagram)
Switch off the power
Set threaded tubes into the power cord and control line
Connect the power and the load with the sensor according to the connection-line diagram

TEST
1.       Turn the light-control potentiometer to Max value, the time delay potentiometer to Min value, the sensitivity potentiometer to Max value, and then switch on the power.The product will enter into normal working state thirty seconds later. Wave your hand in the right front of the sensor window after the indicator switches off, then the sensor will start load to work when it has detected the signal. In the event of no continuous detection, the load will stop working in 8±2s
2.       Turn the light-control potentiometer to Min value, wave your hand in the right front of the sensor window after the indicator switches off, the load won’t work.Cover the sensor window with  PIECE OF NON-TRANSPARENT BLACK CLOTH, THE LOAD STARTS WORKING. In the event of no continuous detection, the load will stop working in 8±2s
3.       Turn the light-control potentiometer to Max value, the time delay potentiometer to Max value, the sensitivity potentiometer to Max value.Wave your hand in the tight front of the sensor window after the indicator switches off, then the sensor will start load to work when it has detected the signal . In the event of no continuous detection, the ;load will stop working in 8±2s

ATTENTION:When use this product, please adjust the sensitivity to an appropriate position you need, please do not adjust the sensitivity to maimun,to avoid the product does not work normally caused by wrong motion.Because the sensitivity is too high easily detect the wrong moion by wind blowing leaves&curtains,small animals,and the wrong motion by interence of power grid&electrical equipment.All those lead product dose not work normally!
When the product does not work normally ,please try to lower the sensitivity appropriately,
And then test it.

Notes
Electrician or experienced human can install it
The unrest objects can’t be regarded the installation basis-face
In front of the detection windw there should be no hinder or unrest objects effecting detection
Avoid installing it near air temperature alteration zones for example:air condition,central heating,ect.
Please don’t open the case for your safety if you find the hitch after installation

Remark
1.       Keep the sensor face to the area where human usually move
2.       Keeo the sensor face to the position of the ambient light in order to get much more exact illuminance setting
3.       If detect the signal again within the time-delay, the time-delay will ba over lied

Some problem and solved way
The load don’t work:
A:Check the power and the load
b.If the load is good
c.olease check  if the working light correspond to the ambient light
The sensitivity is poor:
a.       Please check if in front of the detection window there is hinder that effect to receive the signals
b.       Please check if the ambient temperature is too high
c.       Please check if the signals source  is in the detection fields
d.       If the moving orientation is right
The sensor can’t shut automatically the load:
a.       If there is continual signal in the detection fields
b.       If the time delay is set to the longest
c.       If the power correspond to the instruction
d.       If the air temperature change near the sensor, for example air condition or central heating ect

没有评论: